Servicing
Conventional Boilers
It is highly recommended that oil fired boilers are serviced annually as blocked nozzles and filters can have a major effect on the efficiency of the unit and increase fuel costs by as much as 30%
Full Manufacturers Recommended Service
PRICE £75 + VAT
What we do during our Boiler Service
- Our servicing consists of a full service to the burner , boiler and oil tank;
- We clean the combustion chamber and check all seals and gaskets;
On the burner we:
- Replace The nozzle
- Clean the blast tube
- Check / test solenoids
- Check clean photocell
- Test the ignition transformer
- Disassemble the oil pump off the burner and replace any worn drive couplings
- Open pump clean internal filter
- Lubricate the motors shaft and bearings
- Check and adjust electrode settings
- Reassemble the burner and test, adjusting oil pressure and air settings to the manufactures recommended settings.
What we do during our oil tank Service
- Clean/replace filter or strainer
- inspect tank isolation
- complete tank risk assessment in accordance with OFTEC 600A Training
- Unsure remote and internal fire Valves operate correctly
- Inspect for excessive corrosion and leaks on tanks and pipe work
- Inspect location for safety